Sign In | Join Free | My himfr.com
Home > GPS Fuel Sensor >

Fuel Tank Level Sensor Petrol Level Sensor Used To Fix The Extention Wire

    Buy cheap Fuel Tank Level Sensor Petrol Level Sensor Used To Fix The Extention Wire from wholesalers
     
    Buy cheap Fuel Tank Level Sensor Petrol Level Sensor Used To Fix The Extention Wire from wholesalers
    • Buy cheap Fuel Tank Level Sensor Petrol Level Sensor Used To Fix The Extention Wire from wholesalers
    • Buy cheap Fuel Tank Level Sensor Petrol Level Sensor Used To Fix The Extention Wire from wholesalers

    Fuel Tank Level Sensor Petrol Level Sensor Used To Fix The Extention Wire

    Ask Lasest Price
    Brand Name : caxtrack
    Model Number : CA-201
    Certification : CE/ROHS/FCC/SGS
    Price : negotiation
    Payment Terms : T/T or western Union or paypal
    Supply Ability : 100,000pcs per month
    Delivery Time : 1-10 working days after received your payment
    • Product Details
    • Company Profile

    Fuel Tank Level Sensor Petrol Level Sensor Used To Fix The Extention Wire

    RS232 / RS485 / Analog transmission Capacitor Oil Level Sensor

    Examination area: 100~1000mm

    resolution ratio: 0.1%

    Measuring accuracy:0.1%

    Maximal error of measure :1mm

    heat-resistant :-40~150

    Diameter Φ18mm

    Output signal :4~20mA,0~5V, RS485, RS232, CAN bus

    Voltage supply :DC7~42V

    Rated supply :0.1W

    Fixed type :Screw installation M20X1.5 OR Flange mounting

    Pressure range :-0.1MPa ~ 0.1 MPa

    ambient temperature -40~85℃

    Fuel Tank Level Sensor Petrol Level Sensor Used To Fix The Extention Wire

    2.Instructions

    2.1 definition of the output line

    Interface output line use 6 core cable, connecting definition:


    0~5V output [CA-201A]:

    Black line connect ground wire

    Red line connect positive power

    White line 0~5V voltage signal output,connect voltage signal wire

    Yellow line empty fuel tank use only

    Green line full fuel tank use only


    4~20 mA output [CA-201B]:

    Black line connect ground wire

    Red line connect positive power

    White line 4~20mA ampere signal out put,connect ampere signal line

    Yellow line empty fuel tank use only

    Green line full fuel tank use only


    RS232 output [CA-201C]:

    Black line connect ground wire

    Red line connect positive power

    White line RXD input, connect car RS232 TXD

    Blue line TXD output, connect car RS232 RXD

    Yellow line empty fuel tank use only

    Green line full fuel tank use only


    RS485output mode(CA-201D)

    Black line connect to CND

    red line connect to VDD

    white line connect to RS485 A

    blue line connect to RS485 B

    yellow line marking for empty fuel tank

    green line marking for full fuel tank


    2.2 Calibration

    This sensor adopt high-speed MCU of CNC technology, adopting self-calibration

    Calculation , and leaves out the complicated Manual calibration while using. in normal

    circumstance, the sensor can directly be used in the measurement of the diesel, if need to calibration, you can use the three following ways to complete. (each can work)


    1.self-calibration: put the sensor slowly into the The tested medium while power on, let the liquid get into the feed inlet slowly ,stoping when the liquid is overflew the vent hole of the sensor. and this operation accomplish the calibration of the sensor . In order to prevent the failure of the calibration process , please do this process for at least 2 times .( notice:This way is under the condition of powering on , outage restart will restore the factory Settings.In the condition of empty fuel tank,refueling to full, the sensor itself are also able to complete the self-calibration )


    3.Notice

    1.Only one signal can exist among RS232/ RS485/ 0-5V/ 4~20mA, and you can use either one of them. The trunk of RS485 can meet multiple sensors at the same time, but you should set the address of each sensor in advance. Address of each sensor must be unique, in case the trunk is locked. RS485 trunk is made of half-duplex chips, so when it reading data, you should set aside the corresponding time for the module. The reading speed cannot be too fast: when it reads continuously, the time interval between the two instructions cannot be less than five seconds.

    2.For the signal transmission line, especially the one of RS232,communications circuits should not be too long, and should use the shielded wire.

    3. For the sensors of the signal RS232/ RS485, when debugging the failure of communication, you can exchange the white line and the blue one and test again. If it works then, it is the connection error before. The operation is only for digital communications.

    4. The power supply voltage of sensor cannot be more than the normal working voltage, and the power consumption of the sensor’s power supply cannot be less than the normal working power consumption.

    5. The actual environment should conform to the requirements of the basic parameters of sensors, and shall not exceed the normal range, or it would damage the sensor, even cause other accidents.

    6. On account of oil products, there are differences between the mediums of the calibration and use, users had better operate according to 2.2.2.

    7. Do not remove sensors or damage it maliciously, or we do not guarantee it.

    8.General factory accessories include Flange, rubber blanket, O-Rings, booklet of instruction, certificate of conformity. If you have special needs, please tell us in advance.

    9.Guarantee period of the sensor is one year. All accessories including rubber blanket, O-Rings, are beyond the scope of “ threeguarantees ”.


    Symptom of failure

    1No-output /communication error

    2The output value unchanged

    3Measurement error of output value

    4Output value floats up or down


    cause analysis

    1 Open circuit of the power or voltage too low

    Sensor fault

    Wrong connection of the lines and wires

    2 service voltage abnormal

    external interference

    Sensor jammed

    Sensor fault

    3 service voltage abnormal

    external interference

    Sensor jammed

    autoadaptation uncomplete

    Sensor fault

    4 oil level flow

    service voltage abnormal

    external interference

    Sensor fault


    Exclusion and solutions

    1test connect→test if the voltage is greater than 10V when load→test the supply current [range 3~10mA] → connect method see 2.1,or change over blue and white line[digital communication only]→if all above is regular or current beyond normal range,the sensor occurred failure.

    2Test the supply voltage when load[ex.voltage unstable] → recharge the sensor →test if there is a serious interference around→test whether sensors hole is blockage from top to bottom → execute 2.2.2→If not,the sensor occurred failure.

    3 detect whether service voltage is stable while loading ( if the voltage is unstable) → →whether external have interference→check whether the sensor is jammed → execute the 2.2.2 process →then it should be the sensor fault

    4 check the oil leve is stable → check the service is normal and functional →whether external have interference →execute the 2.2.2 process→then it should be the sensor fault


    remark

    1 4~20mA output supply voltage DC20~28V,current is 4~20mA except communication output

    2Check the tank oil level is float or not,if become regular after recharge,check the interference and the power

    3 it usually can be functional while executing the 2.2.2 process

    4 it usually occur on 0~5V signal


    APPLICATION:


    The ultrasonic fuel level sensor is used for digital recording vehicle refueling, to prevent driver stealing oil , avoid the waste of resources, improve operational efficiency, and improve the traffic safety, strengthen the operation and management level.

    This sensor is applicable to various types of vehicles such as trailers, taxis, buses, concrete mixer truck, engineering machinery, sanitation trucks and other.


    Gurantee:


    1. All of our product is free to use the Tracking service server in 24 hours each day

    2. All of our product there is a 2 year quanlity assurance.

    3. Sample fee will not be returned.


    Product Configuration:


    1. Standard configuration

    1) main device 1 pcs

    2) power line 1 pcs

    3) sensor

    5) Installation cables 1 set

    6) Usage instructions

    7) Warranty card


    Quality Fuel Tank Level Sensor Petrol Level Sensor Used To Fix The Extention Wire for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: SHENZHEN YITUOWULIAN SYSTEM CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category: